This work may not be copied, distributed, displayed, published, reproduced, transmitted, modified, posted, sold, licensed, or used for commercial purposes. By downloading this file, you are agreeing to the publisher’s Terms & Conditions.

Article

Psychiatric Disorders and Quality of Life in Patients With Implantable Cardioverter Defibrillators: A Systematic Review

Ana Claudia C. de Ornelas Maia, MSc; Gastão Soares-Filho, MD, MSc; Valeska Pereira, MSc; Antonio Egidio Nardi, MD, PhD; and Adriana Cardoso Silva, PhD

Published: April 18, 2013

Psychiatric Disorders and Quality of Life in Patients With Implantable Cardioverter Defibrillators: A Systematic Review

 

ABSTRACT

Objective: To systematically review the literature with regard to psychiatric disorders and quality of life in patients with an implantable cardioverter defibrillator.

Data Sources: Research was conducted in 3 databases (ISI Web of Science, PubMed, and PsycINFO) using the terms implantable, cardioverter, defibrillator, quality of life, psych*, anxiety, and depression.

Study Selection: The search yielded 1,399 references. Non-English and repeated references were excluded. After abstract analysis, 42 references were recovered for full-text reading, and 25 articles were selected for this review.

Data Extraction: Research took place in April 2012, and no time restriction was placed on any of the database searches. Review or theoretical articles were excluded, and only clinical trials and epidemiologic studies were selected for this review.

Results: A systematic review of the literature revealed mostly observational prospective cohort studies followed by cross-sectional observational studies and randomized clinical trials. Few studies included in the review were observational retrospective cohort or case-control studies. There are prominent signs and symptoms of anxiety and depression in patients with an implantable cardioverter defibrillator. Disorders include phobic anxiety, posttraumatic stress disorder, panic disorder, somatoform disorder, agoraphobia, and depression. Quality of life in the physical, social, and psychological domains is affected and is related to the intensity and the frequency of the device’s electrical discharge.

Conclusions: Work regarding psychiatric comorbidity in patients with an implantable cardioverter defibrillator has shown that anxiety and depression are common. The patients and their families should be informed by their doctors that the presence of the device minimizes risk of sudden death and allows them to have a normal life.

Prim Care Companion CNS Disord 2013;15(2):doi:10.4088/PCC.12r01456

Submitted: August 6, 2012; accepted January 16, 2013.

Published online: April 18, 2013.

Corresponding author: Ana Claudia C. de Ornelas Maia, MSc, Institute of Psychiatry, Universidade Federal do Rio de Janeiro, INCT Translational Medicine, R Visconde de Pirajá, 407/702, Rio de Janeiro, RJ, 22410-003, Brazil ([email protected]).

Arrhythmias are sudden changes in the regular rhythm of the heart that occur without warning, and tachyarrhythmias are those that present with a heart rate over 100 bpm.1 Among the tachyarrhythmias, ventricular tachycardia and ventricular fibrillation are the most feared because they represent a break in the electrical and mechanical integrity of the heart, with the loss of pump function and high risk of sudden death. To have a cardioversion, ie, a return to normal rhythm, immediate intervention is required with antiarrhythmic drugs (chemical cardioversion) and defibrillation (cardioversion).1-3

Long term, the prevention of new arrhythmia outbreaks and sudden death can be achieved with antiarrhythmic drugs, surgical resection of the arrhythmogenic area, endocardial ablation by catheter, or installation of an implantable cardioverter defibrillator.4,5 Since 1984, the implantable cardioverter defibrillator has been used in primary prevention of sudden death.6 There is evidence that the device is an effective alternative to antiarrhythmic drugs to interrupt ventricular tachycardia and ventricular fibrillation, thus contributing to the reduction of sudden death and improving long-term survival.4-6

The implantable cardioverter defibrillator monitors the heart rate as a conventional pacemaker.4 When ventricular tachycardia or ventricular fibrillation are detected, electrodes implanted in the heart muscle discharge an electric shock in accordance with a predetermined program and revert the arrhythmia.1-4 The shock is very uncomfortable, but most patients tolerate discharges, mainly because they appreciate the severity of their condition and the security that the device provides.1-6

In spite of its function of saving lives, however, the implantable cardioverter defibrillator can cause negative emotional effects among patients. Studies have revealed signs and symptoms of depression and poor quality of life in 30% of patients with an implantable cardioverter defibrillator who are younger than 70 years.7 Furthermore, the first shock sensations occur during moments of arrhythmia and cause anxiety among patients who experience the shock.7-9

This study aims to systematically review the scientific literature regarding the presence of psychiatric comorbidities and the quality of life in patients with an implantable cardioverter defibrillator.

METHOD

The literature review was conducted in 3 databases (ISI Web of Science, PubMed, and PsycINFO) using the terms implantable, cardioverter, defibrillator, quality of life, psych*, anxiety, and depression.

The research took place in April 2012, and no time restriction was placed on any of the database searches. Review or theoretical articles were excluded, and only clinical trials and epidemiologic studies were selected.

RESULTS

A total of 1,399 references were found (720 in PubMed, 649 in ISI Web of Knowledge, and 30 in PsycINFO). From the total, 398 were duplicate references and 204 were not in English. The remaining 797 references underwent abstract analysis and 755 were excluded. Forty-two articles were recovered for full-text reading. After this process, only 25 met the inclusion criteria of articles that assessed the prevalence of psychiatric problems and/or quality of life in patients with an implantable cardioverter defibrillator. These articles included 8 cross-sectional observational studies, 2 retrospective cohort studies, 9 prospective cohort studies, 2 case-control studies, and 4 randomized clinical trials (Figure 1).

Figure 1

Click figure to enlarge

Among the articles that have been published since the first cardioverter defibrillator implant surgery, many studies have been conducted to evaluate the clinical effectiveness and reduction of sudden death among users.9 Other research has been conducted to assess the psychiatric and emotional well-being of patients with a cardioverter defibrillator implant.1-8 Data from the 25 studies found on the subject are shown in Table 1.

Cross-Sectional Observational Studies

Ten cross-sectional observational studies were included. The first study was conducted in 1991 by Morris et al10 7 years after the first cardioverter defibrillator implantation. The authors examined a sample of 20 participants 3 to 21 months after cardioverter defibrillator implantation to identify the psychological impact of the intervention both in patients and in their relatives. The prevalence of psychiatric disorders in this population was 50%; 6 patients were behaviorally maladjusted and specifically phobic, 3 suffered from major depression, and 1 developed panic disorder. The patients and their relatives experienced adverse effects following the first shock scare during the postoperative period.10

Table 1

Click figure to enlarge

clinical points
  • Implantable cardioverter defibrillators, while potentially effective for the prevention of sudden death, may have serious psychological effects for patients and their families.
  • The frequency and intensity of shocks may promote anxiety and depression and may worsen depressive and anxiety disorders among those who already have them.
  • New strategies should be developed to improve quality of life and minimize psychiatric disorders that can be triggered with the implant of a cardioverter defibrillator or the first shock.

In 2004, Godemann et al11 investigated the prevalence of anxiety disorders in 90 patients with an implantable cardioverter defibrillator and found that 16.7% of these patients developed anxiety disorders after the impact of a shock. The prevalence of panic disorder with agoraphobia was higher in patients experiencing an electrical discharge more than 2 times a year than in patients with a single discharge annually (62% vs 10%, respectively, P < .01). The intensity of self-observation of their body was significantly related to the development of anxiety disorders (P < .001).11 Two years later, Leosdottir et al12 surveyed 76 patients with cardioverter defibrillator implants or pacemakers who were 40 to 70 years old and who completed the Hospital Anxiety and Depression Scale (HADS), Beck Anxiety Inventory, Beck Depression Inventory, and Medical Outcomes Study 36-item Short-Form Health Survey (SF-36) quality of life inventory. Forty-five patients had experienced a cardioverter defibrillator electrical discharge and 31 with a pacemaker had not. Both groups had increased symptoms of anxiety and depression. Patients with cardioverter defibrillators were as a group more fearful of death (P = .056) and showed more concerns about returning to work (P = .072). No significant difference in quality of life was noted between the 2 groups. Physical function, mental health, and social function improved with time in both treatment groups, and it was observed that the 45 patients who experienced a shock reported that they would like to be clinically followed in a group.12

In 2009, Jacq et al13 evaluated 40 patients with implantable cardioverter defibrillators who also had comorbidities. They divided the patients into those who had experienced a shock from the device and those who had not. Using the Mini International Neuropsychiatric Interview, HADS, and SF-36, the researchers found that among those who had experienced a shock, 37.5% had anxiety disorder in contrast to 8% in the group who had not experienced a shock.13 Prevalence of depressive disorders was higher in the group that had experienced a shock (50%) than in the group that had not (23%). Also, depressive symptom scores were higher in those who experienced a shock (4.75) than in those who did not (2.24; P=.04). But, the prevalence of depression and the depression scores were not significantly different. However, depression and quality of life differed on the basis of the frequency of the shocks. A positive correlation was found between the number of shocks and the depressive symptom scores (P = .05, r = 0.24). There was a negative correlation between the mental health subscore of the SF-36 and the number of shocks (r = −0.36, P = .003).13

In 2009, van den Broek et al14 investigated general feelings of independence, anxiety, and quality of life among patients with an implantable cardioverter defibrillator and noted signs of anxiety related to cardiorespiratory-specific symptoms that hindered their quality of life. Maryniak et al15 studied 16 patients aged 24 to 73 years with an implantable cardioverter defibrillator who experienced many discharges (from 25 to 200 discharges) or electric shock (≥3 discharges following one after another). They noted that 14 patients were phobic of the shock. In addition, 11 patients had comorbidities: 4 had generalized anxiety, 3 had PTSD, and 4 had depression.15

Versteeg et al16 conducted a study that included 241 patients with an implantable cardioverter defibrillator, of whom 33% were women. These female patients reported more symptoms of anxiety (β = 0.13, P = .04), phobic anxiety (β = 0.13, P = .05), and somatic health complaints (β = 0.15, P = .02) and scored higher on somatosensory amplification (β = 0.24, P < .001) than men.16 In 2011, Arnous et al17 investigated the effectiveness of the cardioverter defibrillator and quality of life among 71 patients who were implanted with the device between 2002 and 2006. Of these patients, 7% had comorbidities. They found that 25% of patients had experienced a shock that they considered beneficial; 10% considered the shock experience to be inappropriate. The authors concluded that cardioverter defibrillator implantation is associated with a high incidence of life-saving therapy, a low complication rate, and a high level of tolerability.17

Retrospective Cohort Studies

In 2002, Carroll et al18 assessed the quality of life before and after cardioverter defibrillator implantation among 70 patients with a mean age of 64 years. There was no agreement among patients with regard to whether living with the cardiac arrhythmia before the implantation or dealing with the shocks after the implantation was worse. Worsening of quality of life occurred more often in social and psychological domains. Further research is needed to identify what actually worsens the quality of life of patients who receive an implantable cardioverter defibrillator.18

In 2009, Jaafari et al19 examined a case report of a patient in whom cardioverter defibrillator implantation triggered worsening of obsessive-compulsive disorder. The patient developed “twiddler’s syndrome,” in which mechanical manipulation can induce the malfunction of the implant. In this case, twiddler’s syndrome resulted from compulsive checking of the device. Two invasive procedures were required to replace the cardioverter defibrillator. Psychiatric intervention prevented the recurrence of twiddler’s syndrome in this patient for more than 2 years of follow-up.19

Prospective Cohort Studies

In 1998, Crow et al20 administered the Structured Clinical Interview for DSM-III-R in 35 patients 3 days after they were implanted with a cardioverter defibrillator and repeated the same interview 9 to 18 months later. Alcohol abuse and dependence were present in 14.3%, 8.6% had comorbid mood disorders, and 5.7% had major depression.20

In 2004, Godemann et al21 investigated the quality of life among 93 patients 1 to 6 years after having a cardioverter defibrillator implanted. In the assessment, 30% had decreased quality of life in the physical domain and experienced phobic anxiety after the first shock.21 In a 2009 study by Noyes et al,22 quality of life was examined among 983 patients with a cardioverter defibrillator at 3, 12, 24, and 36 months after the implantation and following the first shock. The authors noted that following the first shock, 41% experienced negative effects in the physical and psychological domains.22 The overall health-related quality of life was reduced by 0.04 (P = .04) at the assessment following the first shock. The negative effect of cardioverter defibrillator firing on health-related quality of life was an order of magnitude greater than the effect of congestive heart failure. A higher prevalence of congestive heart failure and shocks among patients with cardioverter defibrillator implants and their negative effect on health-related quality of life may partially explain the lack of benefit of the device on health-related quality of life.22

In 2010, Kapa and colleagues23 administered the HADS, SF-36, and Impact of Events Scale-Revised (IES-R) to 308 patients who had been implanted with a cardioverter defibrillator and found that 223 had developed anxiety disorders, especially PTSD. In this study,23 the frequency of PTSD declined from 78 of 223 (35%) at baseline (within 2 months of implantation) to 34 of 223 (15%) at both 6- and 12-month assessments (P < .01). There was a significant improvement over time in HADS (P < .001) and IES-R PTSD scores (P < .001). Patients who experienced shock storms (≥ 3 shocks in 24 h) (n = 5) had significantly higher mean ± SD baseline PTSD scores (29.6 ± 11.4 vs 14.6 ± 11.6, respectively, P < .01). In 2010, Dickerson et al24 examined changes in quality of life 3 months after cardioverter defibrillator implantation in 80 patients and noted that 44.7% reported no change, 20.7% had worsened due to anxiety, and 34.2% had improved. Anxiety state was significantly higher for the worsening group.24 Ladwig et al25 investigated the quality of life in patients with a cardioverter defibrillator after the first year of implantation and found that a high rate of shock increased the anxiety of both patients and their partners, thus worsening their quality of life.

In 2010, Redhead et al26 conducted a survey on the prevalence of anxiety and depression among 106 patients 3 years after cardioverter defibrillator implantation. Experience of shocks and shock storms (≥ 3 shocks in 24 h) increased anxiety significantly from 24% to 34% (P < .01). Experience of shock storms precipitated pathologic levels of anxiety in implant recipients, and need for the device contributed to anxiety in the spouse. Among the patients’ partners, anxiety due to the shocks increased from 24% to 48% and depression from 14% to 22% in all groups.26

In 2012, Marshall et al27 performed a prospective study among 47 patients who had an implantable cardioverter defibrillator for 12 months regarding their quality of life and anxiety. They found that men were more anxious about the shock and that women had a worse quality of life due to worrying about their appearance.27 Fourteen women and 33 men completed a series of questionnaires over a 12-month period. Women reported higher levels of anxiety than men at discharge but over time demonstrated a significant improvement such that at 4, 8, and 12 months men were more anxious.27 Finally, in 2011, von Känel et al28 investigated 107 patients with cardioverter defibrillator implants using the IES-R and found that 30% of these patients were diagnosed with PTSD after the surgery. Mean ± SD PTSD severity increased from baseline to follow-up (19 ± 22 vs 25 ± 19, respectively, P < .001); 19% of patients had PTSD at both assessments, 12% had PTSD at baseline only, and 18% had PTSD at follow-up only. Between 2 and 5.5 years, chronic PTSD related to cardioverter defibrillator placement slightly increased, and nearly one-fifth of patients had newly developed PTSD.28

Case-Control Studies

In 2005, Whang et al29 investigated the prevalence of symptoms of depression after cardioverter defibrillator implantation through the Center for Epidemiologic Studies of Depression by using scales that were tested in 645 coronary patients with the device. Among patients, 14% experienced mild depression and 4% experienced moderate-to-severe depression after the first shock, pointing out the relationship between depression and shock.29 In 2011, Probst et al30 published a study on the hereditary syndrome of bradycardia in a population divided into the following 3 groups: those with cardioverter defibrillator placement who were asymptomatic (group 1), those with cardioverter defibrillator placement who were symptomatic (group 2), and those without the device (group 3). SF-36 questionnaires investigating quality of life were evaluated. The results were statistically significant (60 in group 1, 78 in group 2, and 52 in group 3; P < .001), and the researchers concluded that the patients had a good quality of life with no difference between implanted and nonimplanted patients. However, cardioverter defibrillator implantation was accompanied by difficulties in the patients’ social and professional lives.30

Randomized Clinical Trials

In 2002, Kuijpers et al31 reported anxiety and depression to be very common among 10 patients with an implantable cardioverter defibrillator who had been diagnosed with panic disorder, agoraphobia, and depression. After the use of selective serotonin reuptake inhibitors (SSRIs) combined with a program of cognitive-behavioral therapy performed over 6 months, 4 of 5 patients who received this treatment improved markedly. The total number of ventricular premature beats decreased significantly after treatment.31 In 2007, Crössmann et al32 used clinical monitoring to reduce anxiety disorder in 35 patients with an implantable cardioverter defibrillator. Psychometric measures of anxiety were collected for 2 years and 5 months. During this period, shocks and antitachycardia pacing were assessed. Psychoeducation and relaxation were done as a treatment and resulted in a reduction in anxiety 2 years and 5 months after surgery to control tachycardia.32

In 2010, Mark et al33 used a structured interview to investigate quality of life 12 to 24 months after cardioverter defibrillator implantation and found that patients and their partners participating in a support group had greater quality of life than patients who did not.33 In 2011, Meischke et al34 trained 305 patients with implantable cardioverter defibrillators and their families with live psychoeducation programs or videos that emphasized self-efficacy (belief that one has the power to effect change based on one’s own action) and control (belief that one has the internal and external resources to exert positive changes over one’s illness or caregiving situation). In this study, there were 300 control cases. The researchers found that the beliefs of the patients and their families regarding self-efficacy in managing the device after 3 months of training were more positive than those of patients and families who did not receive training.34

DISCUSSION

According to the available literature, patients with an implantable cardioverter defibrillator require greater emotional attention due to the imminent risk of sudden death. Although the device represents a major innovation in the reduction of sudden cardiac death, it has a negative impact on quality of life and can increase anxiety and depression. The high energy shock from an implantable cardioverter defibrillator is uncomfortable; however, most patients tolerate discharges, mainly because they realize they represent security for their lives.

Initial studies10,11,20,31 of psychiatric comorbidities and poor quality of life in patients with an implantable cardioverter defibrillator reported that the negative effects related to experiencing a shock provoked somatization, phobias, and depressive symptoms that affected their social relations and undermined their quality of life. The age of patients seems to be a factor in determining the degree to which the device interferes with quality of life. Older individuals adapt better compared to younger people.

Anxiety and depressive disorders starting from the first shock were shown to be the most common psychiatric disorders in observational studies10,23 and clinical trials.13,31 However, conducting psychoeducation or providing follow-up information and guidance to patients and their families led to emotional improvement in all selected studies.31-34

Some studies24,30,33 described an improvement in quality of life after implantation due to the decreased risk of sudden death. However, other retrospective observational studies18,19 evaluated the prevalence of psychiatric disorders before and after implantation and noted that existing psychiatric comorbidities worsened after surgery due to increased anxiety. Comparisons29,30 between patients with and without an implantable cardioverter defibrillator showed that anxiety and depression are prevalent with heart disease, even in those potentially requiring the device.

When patients experiencing low rates of shocks are compared with those having many in a brief interval of time, some results require attention. In cases of more than 2 discharges annually, the incidence of panic disorder with agoraphobia was higher than that of patients with a single discharge annually,11 and a positive correlation was found between the number of shocks and depressive symptom scores, and a negative correlation was found between the number of shocks and the mental health subscore of the SF-36.13 Shock discharges over time can be predictors of phobic and anxiety disorders.23

One prospective study showed a high incidence of use and abuse of alcohol associated with psychiatric comorbidities after cardioverter defibrillator implantation.20 There is also a tendency toward worse psychiatric outcome after the first shock, and decreased quality of life in the physical domain and phobic anxiety have been described.21 Negative effects in physical and psychological domains may be present.22

Studies show that families of patients with cardioverter defibrillator implants are affected as well. In those with high rates of shock, partners as well as patients have increased rates of anxiety and consequent low quality of life.25 Shock storms significantly increased anxiety levels of patients and spouses.26

With regard to therapeutic possibilities, prospective studies show the potential benefits of a support intervention. Patients who have obsessive-compulsive disorder can develop an obsessive ritual of checking the device, leading to malfunction. These patients require a psychiatric intervention for a better quality of life.19 Four of 5 patients with cardioverter defibrillator implants who received combined treatment with SSRIs and CBT over 6 months improved markedly.31 Psychoeducation and relaxation were found to reduce anxiety symptoms in 35 patients 2 years and 5 months after surgery.32 Also, 3 months of training regarding self-efficacy and control related to the implantable cardioverter defibrillator improved the beliefs of both patients and their families and resulted in more positive results compared to those who did not receive training.34

We found no reports of psychiatric disorders other than depressive or anxiety disorders. Many of these studies10,11,20,31 reported a low quality of life among patients due to symptoms of anxiety and depression that developed after cardioverter defibrillator implantation. It seems important to know the concerns from the patient’s perspective to ensure that they are addressed and to provide support for families.

CONCLUSION

On the basis of the reviewed studies, it is clear that implantable cardioverter defibrillators, while potentially effective for the prevention of sudden death, may have serious psychological effects for patients and their families. The frequency and intensity of shocks may promote anxiety and depression and may worsen depressive and anxiety disorders among those who already have them.

Among the most common anxiety disorders in patients with implantable cardioverter defibrillators were PTSD, phobias, somatoform disorders, and generalized anxiety and panic, which may occur with or without agoraphobia. Low quality of life due to difficulties related to the physical, psychological, and social domains was observed in patients who developed a depressive disorder.

Not all patients receiving an implantable cardioverter defibrillator get the same therapeutic benefit and have the same risk of psychiatric side effects. An individual’s specific resilience factors may influence his/her course, and with an increase in the number of patients using the device worldwide, is worthy of more detailed research.

This study, in addition to serving as a motivation for further research, provides information for the development of new strategies to improve quality of life and minimize psychiatric disorders that can be triggered with the implant of a cardioverter defibrillator or the first shock. Additionally, patients receiving an implantable cardioverter defibrillator should be informed by their doctors that the presence of the device minimizes risk of death and allows them to have a normal life.

Author affiliations: Laboratory of Panic and Respiration, Institute of Psychiatry (Drs Soares-Filho and Silva and Mss Ornelas Maia and Pereira) and National Institute for Science and Technology, Translational Medicine (Drs Nardi and Silva), Federal University of Rio de Janeiro; and National Institute for Science and Technology, Translational Medicine, Federal University Fluminense (Dr Silva), Rio de Janeiro, Brazil.

Potential conflicts of interest: None reported.

Funding/support: None reported.

REFERENCES

1. Marino, PL. The ICU Book. 3rd ed. Philadelphia, PA: Lippincott Williams & Wilkins. 2007:455.

2. Timerman S; Timerman A; Ramires, JA. Desfibrilação externa automática: aumentando os í­ndices de sobreviventes. Rev. Soc.Cardiol. 1998;8(4):690-715.

3. Myerburg RJ, Castellanos A. Cardiac arrest and sudden cardiac death. In: Braunwald E, Zipes DP, Libby P, eds. Heart Disease: A Textbook of Cardiovascular Medicine. 6th ed. Philadelphia: WBSaunders; 2001:890-931.

4. Gregoratos G, Abrams J, Epstein AE, et al; American College of Cardiology/American Heart Association Task Force on Practice Guidelines/North American Society for Pacing and Electrophysiology Committee to Update the 1998 Pacemaker Guidelines. ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia devices: summary article: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/NASPE Committee to Update the 1998 Pacemaker Guidelines). Circulation. 2002;106(16):2145-2161. PubMed doi:10.1161/01.CIR.0000035996.46455.09

5. Kuck KH, Cappato R, Siebels J, et al. Randomized comparison of antiarrhythmic drug therapy with implantable defibrillators in patients resuscitated from cardiac arrest: the Cardiac Arrest Study Hamburg (CASH). Circulation. 2000;102(7):748-754. PubMed doi:10.1161/01.CIR.102.7.748

6. Carroll SL, Markle-Reid M, Ciliska D, et al. Age and mental health predict early device-specific quality of life in patients receiving prophylactic implantable defibrillators. Can J Cardiol. 2012;28(4):502-507. PubMed doi:10.1016/j.cjca.2012.01.008

7. Bänsch D, Schneider R, Akin I, et al. A new single chamber implantable defibrillator with atrial sensing: a practical demonstration of sensing and ease of implantation. J Vis Exp. 2012;(60):pii: 3750. PubMed

8. Wever EF, Hauer RN. Cost-effectiveness considerations: the Dutch prospective study of the automatic implantable cardioverter defibrillator as first-choice therapy. Pacing Clin Electrophysiol. 1992;15(4 pt 3):690-693. PubMed doi:10.1111/j.1540-8159.1992.tb05164.x

9. Lickfett L, Bitzen A, Arepally A, et al. Incidence of venous obstruction following insertion of an implantable cardioverter defibrillator. A study of systematic contrast venography on patients presenting for their first elective ICD generator replacement. Europace. 2004;6(1):25-31. PubMed doi:10.1016/j.eupc.2003.09.001

10. Morris PL, Badger J, Chmielewski C, et al. Psychiatric morbidity following implantation of the automatic implantable cardioverter defibrillator. Psychosomatics. 1991;32(1):58-64. PubMed doi:10.1016/S0033-3182(91)72112-9

11. Godemann F, Butter C, Lampe F, et al. Panic disorders and agoraphobia: side effects of treatment with an implantable cardioverter/defibrillator. Clin Cardiol. 2004;27(6):321-326. PubMed doi:10.1002/clc.4960270604

12. Leosdottir M, Sigurdsson E, Reimarsdottir G, et al. Health-related quality of life of patients with implantable cardioverter defibrillators compared with that of pacemaker recipients. Europace. 2006;8(3):168-174. PubMed doi:10.1093/europace/euj052

13. Jacq F, Foulldrin G, Savouré A, et al. A comparison of anxiety, depression and quality of life between device shock and nonshock groups in implantable cardioverter defibrillator recipients. Gen Hosp Psychiatry. 2009;31(3):266-273. PubMed doi:10.1016/j.genhosppsych.2009.01.003

14. van den Broek KC, Nyklí­cek I, Denollet J. Anxiety predicts poor perceived health in patients with an implantable defibrillator. Psychosomatics. 2009;50(5):483-492. PubMed

15. Maryniak A, Szumowski L, Orczykowski M, et al. Anxiety and depression among the patients with frequent implantable cardioverter-defibrillator discharges. Int J Cardiol. 2009;132(2):e80-e81. PubMed doi:10.1016/j.ijcard.2007.08.027

16. Versteeg H, Baumert J, Kolb C, et al. Somatosensory amplification mediates sex differences in psychological distress among cardioverter-defibrillator patients. Health Psychol. 2010;29(5):477-483. PubMed doi:10.1037/a0020337

17. Arnous S, Murphy NF, Pyne-Daly P, et al. Clinical and psychological impact of prophylactic implantable cardioverter-defibrillators in a community heart failure population. Ir J Med Sci. 2011;180(2):369-374. PubMed doi:10.1007/s11845-010-0659-z

18. Carroll DL, Hamilton GA, Kenney BJ. Changes in health status, psychological distress, and quality of life in implantable cardioverter defibrillator recipients between 6 months and 1 year after implantation. Eur J Cardiovasc Nurs. 2002;1(3):213-219. PubMed doi:10.1016/S1474-5151(02)00040-3

19. Jaafari N, Bachollet MS, Paillot C, et al. Obsessive compulsive disorder in a patient with twiddler’s syndrome. Pacing Clin Electrophysiol. 2009;32(3):399-402. PubMed doi:10.1111/j.1540-8159.2008.02251.x

20. Crow SJ, Collins J, Justic M, et al. Psychopathology following cardioverter defibrillator implantation. Psychosomatics. 1998;39(4):305-310. PubMed doi:10.1016/S0033-3182(98)71318-0

21. Godemann F, Butter C, Lampe F, et al. Determinants of the quality of life (QoL) in patients with an implantable cardioverter defibrillator recipients between 6 months and 1 year after implantation. Eur J Cardiovasc Nurs. 2004;13(2):411-416. PubMed

22. Noyes K, Corona E, Veazie P, et al. Examination of the effect of implantable cardioverter-defibrillators on health-related quality of life: based on results from the Multicenter Automatic Defibrillator Trial-II. Am J Cardiovasc Drugs. 2009;9(6):393-400. PubMed doi:10.2165/11317980-000000000-00000

23. Kapa S, Rotondi-Trevisan D, Mariano Z, et al. Psychopathology in patients with ICDs over time: results of a prospective study. Pacing Clin Electrophysiol. 2010;33(2):198-208. PubMed doi:10.1111/j.1540-8159.2009.02599.x

24. Dickerson SS, Kennedy M, Wu YW, et al. Factors related to quality-of-life pattern changes in recipients of implantable defibrillators. Heart Lung. 2010;39(6):466-476. PubMed doi:10.1016/j.hrtlng.2009.10.022

25. Ladwig KH, Ronel J, Baumert J, et al. Psychological comorbidity and quality of life in patients with an implantable cardioverter/defribrillator (ICD). Herzschrittmacherther Elektrophysiol. 2010;21(2):129-136. PubMed doi:10.1007/s00399-010-0082-1

26. Redhead AP, Turkington D, Rao S, et al. Psychopathology in postinfarction patients implanted with cardioverter-defibrillators for secondary prevention. a cross-sectional, case-controlled study. J Psychosom Res. 2010;69(6):555-563. PubMed doi:10.1016/j.jpsychores.2010.06.002

27. Marshall P, Ketchell A, Maclean J. Comparison of male and female psychological outcomes related to implantable cardioverter defibrillators (COMFORTID). Eur J Cardiovasc Nurs. 2012;11(3):313-321. PubMed

28. von Känel R, Baumert J, Kolb C, et al. Chronic posttraumatic stress and its predictors in patients living with an implantable cardioverter defibrillator. J Affect Disord. 2011;131(1-3):344-352. PubMed doi:10.1016/j.jad.2010.12.002

29. Whang W, Albert CM, Sears SF Jr, et al; TOVA Study Investigators. Depression as a predictor for appropriate shocks among patients with implantable cardioverter-defibrillators: results from the Triggers of Ventricular Arrhythmias (TOVA) study. J Am Coll Cardiol. 2005;45(7):1090-1095. PubMed doi:10.1016/j.jacc.2004.12.053

30. Probst V, Plassard-Kerdoncuf D, Mansourati J, et al. The psychological impact of implantable cardioverter defibrillator implantation on Brugada syndrome patients. Europace. 2011;13(7):1034-1039. PubMed doi:10.1093/europace/eur060

31. Kuijpers PM, Honig A, Wellens HJ. Effect of treatment of panic disorder in patients with frequent ICD discharges: a pilot study. Gen Hosp Psychiatry. 2002;24(3):181-184. PubMed doi:10.1016/S0163-8343(02)00176-7

32. Crössmann A, Pauli P, Dengler W, et al. Stability and cause of anxiety in patients with an implantable cardioverter-defibrillator: a longitudinal two-year follow-up. Heart Lung. 2007;36(2):87-95. PubMed doi:10.1016/j.hrtlng.2006.08.001

33. Mark DB, Anstrom KJ, McNulty SE, et al. Quality of life effects of automatic external defibrillators in the home: results from the Home Automatic External Defibrillator Trial (HAT). Am Heart J. 2010;159(4):627-634.e7. PubMed doi:10.1016/j.ahj.2010.01.013

34. Meischke H, Diehr P, Phelps R, et al. Psychologic effects of automated external defibrillator training: a randomized trial. Heart Lung. 2011;40(6):502-510. PubMed doi:10.1016/j.hrtlng.2010.12.009

Related Articles

Volume: 15

Quick Links: Cardiology , Medical

$40.00

Buy this Article as a PDF

References